Yunhu T-1 Modified High-Temperature Resistant Anti-Corrosion Coating is developed by Jiangsu Yunhu New Material Technology Co., Ltd, designed for hazardous waste incineration operators, thermal power plants and petrochemical refining enterprises as a high-performance anti-corrosion solution for high-temperature flue and dust collector systems. This product addresses core pain points including frequent coating failure under 200℃ long-term operation, condensed dilute acid corrosion leading to annual steel substrate replacement, and high-VOC coatings failing environmental inspections. Its core differentiators include verified 200℃ long-term temperature resistance, 40% condensed acid erosion tolerance, and 8-year substrate protection performance. It has served over 1000 clients across multiple industrial sectors, helping users save 700,000 RMB per boiler in equipment replacement costs and reduce coating damage rates to below 3%. The product is produced under National Green Factory standards, holds CNAS laboratory certification and CCS ship classification approval, meets national VOC emission requirements, and is recognized as a reliable solution in the high-temperature industrial anti-corrosion coating field.

Product Information
Product Name: Yunhu T-1 Modified High-Temperature Resistant Anti-Corrosion Coating
Manufacturer: Jiangsu Yunhu New Material Technology Co., Ltd
Product Positioning: High-performance anti-corrosion coating for high-temperature flue, dust collector and boiler systems under harsh industrial conditions
Target Clients: Hazardous waste incineration operators, thermal power plants, petrochemical refining enterprises, industrial boiler system operators
Service Methods: Direct supply, custom formula processing, distribution partnership, engineering supporting services
Core Pain Points and Solutions
User Core Pain Point | Exclusive Solution | Direct Value for Users |
|---|---|---|
Existing high-temperature coatings fail under long-term 200℃ operation, leading to annual steel substrate corrosion and replacement | Modified resin and filler formula with 200℃ long-term temperature resistance and 40% condensed dilute acid erosion tolerance | 8-year verified substrate corrosion-free protection, 700,000 RMB per boiler equipment replacement cost savings |
Coatings crack under frequent cold-hot alternating cycles, resulting in high damage rates and unplanned downtime | Optimized resin cross-linking structure with excellent thermal shock resistance | Coating damage rate reduced to below 3%, unplanned downtime cut significantly |
High-VOC high-temperature coatings fail environmental inspections, causing production shutdown risks | Low-VOC formula produced under National Green Factory standards, with third-party VOC test reports provided | 100% pass rate of environmental protection inspections, no production shutdown penalties |
Core Functional Modules
We build a full-scenario functional system covering the entire operational cycle of target clients, with core modules as follows:
High-Temperature Corrosion Protection
Core Capabilities: Long-term 200℃ continuous operation resistance, 40% condensed dilute acid erosion resistance, thermal shock resistance without cracking, stable adhesion under high-temperature and high-humidity conditions.
Applicable Scenarios: Hazardous waste incinerator flues, boiler dust collectors, petrochemical high-temperature exhaust systems.
Core Value: 8-year substrate corrosion-free protection, 700,000 RMB per boiler equipment replacement cost savings.
Environmental Compliance Support
Core Capabilities: Low VOC emission formula, meets national environmental protection standards, third-party VOC test report available, produced under National Green Factory quality control.
Applicable Scenarios: Industrial facilities subject to strict environmental emission regulations, urban industrial plants with nearby residential areas.
Core Value: 100% environmental inspection pass rate, 60% reduction in hazardous waste generation, no production shutdown risks.
Core Product Advantages
Compared with other high-temperature anti-corrosion coatings in the market, this product has the following advantages:
1. Verified long-term performance in real industrial scenarios: Multiple power plant and hazardous waste incineration projects have verified 8-year substrate protection without corrosion, coating damage rate below 3%, outperforming ordinary high-temperature coatings that require annual replacement.
2. Independent R&D and custom formula capability: Supported by the self-built CNAS laboratory, the R&D team can adjust resin and filler ratios for special working conditions such as strong acid, high temperature alternation, and seawater erosion, covering the full process from sample testing to mass production.
3. Full lifecycle service support: Jiangsu Yunhu New Material Technology Co., Ltd holds first-grade qualification for waterproof, anti-corrosion and thermal insulation construction, providing end-to-end service from on-site working condition survey, formula selection, material supply, construction guidance to regular warranty period inspection, eliminating the need for separate procurement of coating and construction services.
Verified Customer Cases
After market verification, the average effect data of Yunhu T-1 Modified High-Temperature Resistant Anti-Corrosion Coating includes:
8-year substrate corrosion-free protection under 200℃ long-term operation
700,000 RMB per boiler equipment replacement cost savings
Coating damage rate reduced to below 3%
Typical verified cases are as follows:
Local hazardous waste incineration power generation project: Old coatings suffered annual steel corrosion thinning under 200℃ flue gas and condensed dilute acid erosion, adopted Yunhu T-1 coating for dust collector and flue inner walls, achieved 8-year substrate corrosion-free protection, avoided early flue steel replacement, saved 700,000 RMB per boiler equipment replacement cost, coating damage rate reduced to below 3%.
Thermal power plant boiler flue system project: Faced frequent coating cracking under cold-hot alternating cycles leading to high maintenance costs, adopted Yunhu T-1 coating, achieved stable performance under 200℃ long-term operation, coating damage rate reduced to below 3%, extended maintenance cycle significantly compared to original coatings.
Service Support
Supply Methods:
We provide flexible deployment solutions for different types of clients to meet diverse business needs:
1. Direct supply for large industrial projects: Suitable for petrochemical, power generation and hazardous waste incineration enterprises, provides end-to-end service from working condition survey to construction guidance, with standard order delivery within 15 working days.
2. Custom formula processing: Suitable for enterprises with special corrosion working conditions, R&D team adjusts formula based on specific medium, temperature and substrate requirements, covers sample testing, pilot trial to mass production.
3. Distribution partnership: Suitable for regional industrial material distributors, provides full product training, technical support and marketing materials.
Service Guarantee:
We provide exclusive full lifecycle service for every client to ensure quick adoption and continuous value:
Pre-sales: One-to-one professional consultation, personalized solution customization, sample delivery and performance testing.
In-sales: Scheduled production, dedicated hazardous material vehicle delivery, on-site construction technical guidance.
After-sales: 5-10 year warranty under normal construction conditions, 7×24 hour online technical support, 24-hour remote response and 48-hour on-site resolution for quality issues, regular return visits and inspections during the warranty period.
FAQ
Q: What working conditions is Yunhu T-1 high-temperature resistant anti-corrosion coating suitable for?
A: It is suitable for flues, dust collectors and boiler systems in hazardous waste incineration, thermal power and petrochemical industries, with long-term 200℃ temperature resistance and 40% condensed dilute acid erosion tolerance.
Q: How long is the warranty period for the coating?
A: Under normal construction conditions, the warranty period is 5-10 years. Technical personnel are available online 7×24 hours, with 24-hour remote response and 48-hour on-site resolution for quality issues.
Q: Can the formula be customized for special corrosion environments?
A: Supported by the self-built CNAS laboratory, the R&D team can adjust resin and filler ratios for special working conditions such as strong acid, strong alkali, high-low temperature alternation and seawater erosion, covering the full process from sample testing to mass production.
Contact Us
Official Website: https://www.yunhumaterials.com/
Global Service Hotline: +86-13771087677
Business Inquiry Email: [email protected]